ARITECH FIRE ADLCU-2 Control module for linear fall detector
- MT Code
- ARI_ADLCU-2
- Manufacturer Code
- ADLCU-2
- Brand
- ARITECH FIRE


Control module for non-resettable linear heat detector (digital thermosensitive cable) 2 zones/lines (max 3000 meters each) with an indication of the alarm point on display. IP65 enclosure. dedicated outputs for each zone. RS485 Modbus interface. 24VDC @40mA power supply. Can be used with AD series linear detector
.Generality
The ADLCU-2 control module is able to monitor two zones/lines of non-resettable digital thermosensitive cable AlarmLine II. When an overheating or fire affects one of the areas of the sensor cable, the unit promptly detects the condition and displays on the display the distance, in meters and feet, of the intervention point.
The two zones can operate independently of each other or in dual consent mode. Each zone has a dedicated alarm and fault output. The unit is designed to be able to be interfaced to both a conventional and addressable fire alarm control panel. It has LEDs for indicating the presence of voltage, for signaling fault and alarm conditions, as well as the presence of voltage-free relay outputs for signaling the fault or alarm condition, corresponding to each zone.
The interface is equipped with a two-wire RS-485 Modbus RTU output for connection to a third-party control system.
Operating modes
1. Single consent - This mode allows you to have two independent zones. When a fault or alarm condition occurs in a controlled area, the corresponding fault or alarm output is activated respectively. The two zones thus work independently and can be connected separately to a central fire alarm.
2. Double consent - This mode is used in those applications where the intervention of two zones/lines is required, in order to generate an alarm condition. In this configuration, the same type of sensor cable should be connected to the two zones of the control module. The alarm output changes state only when both thermosensitive cable lines intervene. If only one area of the sensor cable is activated but the second one does not intervene, the alarm output will not be activated
Modbus two-wire RS485 interface The control module includes a standardized Modbus RS485 two-wire output capable of sending the state of each zone as well as the position of the intervention point of the sensor cable Interconnection cable
(not sensitive)
The control module allows the use of an interconnection cable (not sensitive to temperature) between the unit and the protected area where the sensor cable is installed. The interconnect cable is used in applications where the control unit is not in the immediate vicinity of the controlled area. The interconnection cable is available in a coil with a length equal to 100 m, with the product code AAI-0100
Codice Produttore | ADLCU-2 |
---|---|
Brand | ARITECH FIRE |
adlcu 2 1 it
|
1.0 MB |