Description

Microprocessor fire detection and extinguishing control unit equipped with 3 detection zones and 1 extinguishing channel. Internal space for housing 2 12V/7.5Ah batteries. EN 54-2. 54-4 and EN12094 certification. Version with advanced features for networking to 2X series control units (requires a 2010-1-NB card)

General
The control units of the 1X range are able to guarantee simple but extremely advanced solutions for applications in small and medium-sized conventional systems. They are characterized by a contemporary design that can adapt to any environment. The curvature of the front door further characterizes its shapes, making it an important distinctive sign. The operator controls are available on the front panel and enclosed in a highly visible area in black lexan.


With the possibility of supporting different lines of conventional detectors and accessories, these systems, simple to program and configure, offer the widest versatility of use, highlighted by the countless benefits for system users, installers and maintainers.

The 1X-X3E
control unit is a conventional fire detection and extinguishing unit with advanced functionalities and installable within a proprietary network. It is equipped with 3 fire detection zones capable of supporting up to 32 devices per zone. The zones can be programmed in single extinction control mode or configured for a dual-zone extinction command in any combination between them. The control unit also has supervised outputs for a first and second level alarm phase, optical alarm indications and actuator activation. Standard relay outputs are available in accordance with EN54 standards and for system status reporting. There are also multiple system control inputs

.

Options
The 1X-X3E control unit supports, as an option to the standard configuration, 2 different models of relay cards, the first with 4 standard-type relay outputs and the second with 4 supervised relay outputs. Through these cards, the control unit will be able to support up to 16 additional outputs.
The 1X-X3E control unit, through the use of an optional network module, is able to support a network with up to 32 nodes of both conventional 1X series and analog/addressed 2X series control units. The connection can be made both in class A (redundant ring) and in class B (standard bus). This solution allows total remote control from other system nodes, ensuring total flexibility and optimal management and planning of the system

.

Standards and approvals The product complies and certifies according to the following standards:





• EN 54:2, EN 54:4 and CE approval • CPR certification • EN12094-1 certification • WEEE compliant • RoHS


compliant
Data Sheet
Codice Produttore 1X-X3E-10
Brand ARITECH FIRE
Download
Need Help?
Print product sheet
See prices, shop online, and manage your order history
Forgot Password
Not a Customer Yet?
Register
Need Help?
Customer Support
Phone and WhatsApp
Send Email
extra discount
Add to Cart also
You might be interested in
Recently viewed